Installation – Desa VGL18NRA User Manual

Page 9

Advertising
background image

www.desatech.com

112882-01D

9

CAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in

the air exist, may discolor walls

or cause odors.

IMPORTANT:

Vent-free heaters add moisture

to the air. Although this is beneficial, installing

heater in rooms without enough ventilation air may

cause mildew to form from too much moisture.

See Air for Combustion and Ventilation, pages

6 through 8.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP)

for your unit. If your gas supply is not correct, do

not install heater. Call dealer where you bought

heater for proper type heater.

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

INSTALLATION AND CLEARANCES
(Vent-Free Operation Only)

WARNING: Maintain the

minimum clearances. If you

can, provide greater clearances

from floor, ceiling and adjoining

wall.

INSTALLATION

Continued

Carefully follow the instructions below. This will

ensure safe installation into a masonry, UL127-listed

manufactured fireplace or listed vent-free firebox.
Minimum Clearances for Side Combustible
Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 4.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 4).

Note:

When installing your gas logs into

a manufactured firebox, follow firebox

manufacturerʼs instructions for minimum

clearances to combustible materials.

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42 inches.

LOG SIZING REQUIREMENTS

Minimum Firebox Size

Log

Front

Rear

Size

Height Depth Width Width*

18",24", 17"

13"

28"

21"

30"
Minimum Firebox Size With Blower
18",24", 17"

14"

34"

22

3

/

8

"

30"

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

18", 24", 30"

16"

42"

*Measured at 13" depth

Figure 4 - Minimum Clearance for Side

Combustible Material, Side Wall and

Ceiling

*Minimum 16 inches from Side Wall

*

Example

NOTICE: Manual control heaters

may be used as a vented product.

If so, you must always run heater

with chimney flue damper open. If

running heater with damper open,

noncombustible material above fire-

place opening is not needed. Go to

Installing Damper Clamp Accessory

for Vented Operation, page 12.