Troubleshooting – Desa VGL18NRA User Manual

Page 25

Advertising
background image

www.desatech.com

112882-01D

25

OBSERVED PROBLEM

ODS/pilot lights but flame goes

out when control knob is re-

leased

One or both burners do not light

after ODS/pilot is lit

Delayed ignition burner

Burner backfiring during com-

bustion

Slight smoke or odor during initial

operation

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Control knob not fully

pressed in

2. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Pilot flame not touching

thermocouple, which allows

thermocouple to cool, caus-

ing pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged

7. Control valve damaged

1. Inlet gas pressure is too low

2. Burner orifice(s) clogged

3. Mislocated crossover tube

4. Remote selector in OFF

position

5. Wire disconnected from gas

control

1. Manifold pressure is too

low

2. Burner orifice clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

3. Residues from manufacturing

processes and logs curing

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in 30

seconds

3. Fully open equipment shutoff

valve

4. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see

Cleaning and Maintenance,

page 23) or replace ODS/pilot

assembly

5. Hand tighten until snug, then

tighten 1/4 turn more

6. Replace pilot assembly

7. Replace control valve

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 23) or

replace burner orifice(s)

3. Contact qualified service person

4. Put remote selector in ON

position

5. See Wiring Diagram, page 28

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner (see Cleaning

and Maintenance, page 23) or

replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 23) or

replace burner orifice

2. Replace damaged burner

3. Replace gas control

1. Check burner for dirt and

debris. If found, clean burner

(see Cleaning and Mainte-

nance, page 23)

2. Replace gas control

3. Problem will stop after a few

hours of operation

Advertising
This manual is related to the following products: