Operating heater – Desa VGL18NRA User Manual

Page 20

Advertising
background image

www.desatech.com

112882-01D

20

Figure 20 - Pilot

Ignitor
Electrode

Pilot Burner

Ignitor
Electrode

Pilot Burner

Propane/LP Gas

Natural Gas

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the

OFF position.

2a. Set selector switch in the OFF position.

2b.

If Using Optional Hand-Held remote:

Set

selector switch in the OFF position to keep

from draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot

lit by doing one of the following:

1. Turn control knob clockwise

to the

PILOT position.

2. Use remote control manual OFF button.

3. Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 6 under Lighting

Instructions, beginning on page 19.

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 9 under

Lighting Instructions, column 1.

OPERATING HEATER

Continued

5. Press in and turn control knob counter-

clockwise

to the PILOT position.

Press in control knob for five (5) seconds

(see Figure 28).

Note:

You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

6. With control knob pressed in, press and

release electronic ignitor button. This will

light pilot. Hold in ignitor button until pilot

lights.

Note:

If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service person

or gas supplier for repairs.

Note:

If pilot goes out, repeat steps 3

through 7 beginning on page 19.

8. Slightly push in and turn control knob coun-

terclockwise

to the ON position.

9. Set flame adjustment knob to any level

between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Control Knob

Electronic
Ignitor Button

Flame Adjustment Knob

Figure 28 - Control Knob and Ignitor

Button Location

Advertising