Inspecting burners, Operating heater – Desa VGL18NRA User Manual

Page 22

Advertising
background image

www.desatech.com

112882-01D

22

Figure 34 - Incorrect Pilot Flame Pattern

Figure 33 - Correct Pilot Flame Pattern

Pilot Burner

Propane/LP Gas

Natural Gas

Thermocouple

OPERATING HEATER

Continued

Pilot Burner

Thermocouple

Propane/LP Gas

Natural Gas

MAIN BURNER

Periodically inspect all burner flame holes with

the heater running. All slotted burner flame holes

should be open with yellow flame present. All

round burner flame holes should be open with a

small blue flame present. Some burner flame holes

may become blocked by debris or rust, with no

flame present. If so, turn off heater and let cool.

Remove blockage, blocked burner flame holes

will create soot.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat-

terns often.

PILOT FLAME PATTERN

Figure 33 shows a correct pilot flame pattern.

Figure 34 shows an incorrect pilot flame pattern.

The incorrect pilot flame is not properly heating

the thermocouple. When the thermocouple cools,

the heater will shut down. If pilot flame pattern is

incorrect, as shown in Figure 34
• turn heater off (see To Turn Off Gas to Appli-

ance

, page 20)

• see Troubleshooting, page 24
Note:

The pilot flame on natural gas units will

have a slight curve, but the flame should be blue

and have no yellow or orange color.

4. Press the POWER and LOCK buttons

together to turn off the fireplace

Note:

Do not leave the hand-held remote in

the AUTO mode close to the fireplace. The

radiant heat from the fireplace will turn off the

fireplace. Ideally, place the hand-held remote

in the center of the room facing towards the

fireplace.
Note:

Do not hold the hand-held remote for

a long time. Body temperature will affect its

operation in the AUTO mode.
Safety Features

When away from home for an extended period

of time or as a child safety feature to prevent

accidental ignition of the fireplace, the receiver

ON/OFF/REMOTE switch should be in the

OFF position.
Auto Shutoff Feature

1. If the average room temperature exceeds

82 degrees Fahrenheit (28 degrees Centi-

grade), the hand-held remote control will

perform a safety override and shut the

fireplace off. This feature is not available

in the MANU mode.

2. The receiver continuously receives signals

from the hand-held remote to control the

room temperature. If the hand-held remote

is misplaced, obstructed or for any reason

cannot transmit to the receiver, the receiver

will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock

the keypad on the hand-held remote in the

MANU or AUTO mode to prevent inadvertent

operation (i.e. children operating the hand-held

remote control, etc.). The keypad is locked in

either on or off. Press the POWER and LOCK

buttons together to turn the unit on or off.

Advertising