Troubleshooting – Desa VGL18NRA User Manual

Page 24

Advertising
background image

www.desatech.com

112882-01D

24

TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note:

All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or wet

3. Broken ignitor cable

4. Bad battery

5. Ignitor electrode broken

6. Battery not installed, battery

power low or battery not

installed correctly (electronic

ignition models only)

7. Ignitor electrode positioned

wrong

1. Gas supply turned off or equip-

ment shutoff valve closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when in-

stalled

5. Depleted gas supply (pro-

pane/LP only)

6. ODS/pilot is clogged

7. Gas regulator setting is not

correct

OBSERVED PROBLEM

When ignitor button is pressed,

there is no spark at ODS/pilot

When ignitor button is pressed,

there is spark at ODS/pilot but

no ignition

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched

by any metal or tubing. Keep

ignitor cable dry

3. Replace ignitor cable

4. Replace battery

5. Replace pilot assembly

6. Install new alkaline battery in

electronic ignitor. Verify bat-

tery is installed correctly

7. Replace pilot assembly

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while in

PILOT position

4. Continue holding down con-

trol knob. Repeat igniting op-

eration until air is removed

5. Contact local propane/LP gas

company

6. Clean ODS/pilot (see Cleaning

and Maintenance, page 23) or

replace ODS/pilot assembly

7. Replace gas control

Advertising