Figure 4-10: post trigger – ADLINK DAQe-2006 User Manual
Page 54
                                    Advertising
                                    
                                        
                                    
                                
                                 
42
Operation Theory
NOTE
The M_counter defined in Middle-Trigger is different from 
that of the Pre-Trigger. In Middle-Trigger, M_Counter 
ends counting before the trigger event while in Pre-Trig-
ger, M_Counter ends counting right at or before trigger 
event. Refer to Figure 4-6 and Figure 4-9.
Post-Trigger Acquisition
Use post-trigger acquisition in applications where you want to col-
lect data after a trigger event. The number of scans after the trig-
ger is specified in PSC_counter, as illustrated in Figure 4-10. The
total acquired data length = number of enable-channel *
PSC_counter.
Figure 4-10: Post trigger
                                    Advertising