Operation Theory

NOTE

The High_Threshold setting should be always higher
than the Low_Threshold voltage setting.

Figure 4-34: Inside-Region Analog Trigger Condition

High-Hysteresis analog trigger condition

Figure 4-35 shows the high-hysteresis analog trigger condition,
the trigger signal is generated when the input analog signal
level is greater than the High_Threshold voltage, and the
Low_Threshold voltage determines the hysteresis duration.
Note the High_Threshold setting should be always higher then
the Low_Threshold voltage setting.

Figure 4-35: High-Hysteresis Analog Trigger Condition