ADLINK ACL-8112 Series User Manual

Page 54

Advertising
background image

46

Operation Theory

I/O Address

The 8254 in the ACL-8112 occupies four I/O address as shown below.

BASE + 0

LSB OR MSB OF COUNTER 0

BASE + 1

LSB OR MSB OF COUNTER 1

BASE + 2

LSB OR MSB OF COUNTER 2

BASE + 3

CONTROL BYTE

The programming of the 8254 is control by registers BASE+0 to BASE+3.
The function of each register is specified in this section. For more detailed
information, refer to the 8254 handbook.

Control Byte

Before loading or reading any of these individual counters, the control byte
(BASE+3) must be loaded first. The format of the control byte is:

Bit

7

6

5

4

3

2

1

0

SC1 SC0 RL1 RL0 M2 M1 M0 BCD

SC1 & SC0 - Select Counter ( Bit7 & Bit 6)

SC1

SC0

COUNTER

0

0

Select Counter 0

0

1

Select Counter 1

1

0

Select Counter 2

1 1

ILLEGAL

RL1 & RL0 - Select Read/Load operation ( Bit 5 & Bit 4)

RL1

RL0

OPERATION

0

0

COUNTER LATCH FOR STABLE READ

0

1

READ/LOAD LSB ONLY

1

0

READ/LOAD MSB ONLY

1

1

READ/LOAD LSB FIRST, THEN MSB