ADLINK PCI-7200 User Manual

Page 39

Advertising
background image

Register Format

27

I_REQ: Input REQ Strobe Enabled

1: Use I_REQ edge to latch input data
0: I_REQ is disabled

I_TIME0: Input Timer 0 Enable

1: Input is sampled by falling edge of Counter 0 output

(COUT0)
0: Input Timer 0 is disabled

I_FIFO: Input FIFO Enable Mode

1: Input FIFO is enabled (input data is saved to input FIFO)
0: Input FIFO is disabled

TRGPOL: Input Trigger Polarity

1: I_TRG is Rising Edge Active
0: I_TRG is Falling Edge Active

I_TRG: External Trigger Enable

1: Wait until I_TRG signal is active, digital input sampling will

begin after a rising or falling edge of I_TRG
0: Start input sampling immediately (if input control register

is set)

DIN_EN: Digital Input Enable

1: Digital Input Enable
0: Digital Input Disabled, when this bit is set as 0, all digital

input operation will be stopped

X

Digital Output Mode Setting:

O_ACK: Output ACK Enable

1: Output ACK is enabled; the output circuit will wait for

O_ACK after O_REQ strobe is asserted
0: Output ACK is disabled

O_REQ: Output REQ Enable

1: Output REQ is enabled; an O_REQ strobe will be gener-

ated after output data is ready
0: Output REQ is disabled

O_TIME1: Output Timer 1 Enable

1: Output Timer 1 is enabled; output data is moved from out-

Advertising