ADLINK PCI-7200 User Manual

Page 40

Advertising
background image

28

Register Format

put FIFO to DO registers when output of Counter1 goes low
0: Output Counter 1 is disabled

O_FIFO: Output FIFO Enable

1: Output FIFO is enabled (output data is moved from output

FIFO)
0: Output FIFO is disabled

O_TRG: Digital Output Trigger Signal

This bit is used to control the O_TRG output of PCI-7200; the

signal is on CN1 pin 36 of PCI-7200, CN1 pin 26 of cPCI-

7200, CN2 pin 34 of LPCI 7200S when
1: O_TRG 1 goes High (1)
0: O_TRG 1 goes Low (0)

X

Digital I/O FIFO Status:

I_OVR: Input data overrun

1: Digital Input FIFO is full (overrun) during input data trans-

fer
0: No input data overrun occurred
Input data overrun occurred, the I_OVR bit is set when input

FIFO is full and there is new input data coming in. This bit

can be cleared by writing “1” to it.

O_UND: Output data FIFO is underrun

1: Output FIFO is empty during output data transfer
0: No output data underrun occurred
Output data underrun, the O_UND bit is set when output

FIFO is empty and the output request for new data, this bit

can be cleared by writing “1” to it.

Advertising