2.5 Base Address Setting

The ACL-7120A requires eight consecutive address locations in the I/O
address space. The base address of the ACL-7120A is restricted by the
following conditions:

1. The base address must be within the range 200hex to 3FFhex.

2. The base address should not conflict with any PC I/O address.

The ACL-7120A default I/O port base address 0x2A0 is set by the 6 position
DIP switch SW1 (refer to Figure 2.2). Possible address settings for I/O ports
are from Hex 200 to Hex 3FE and are listed in Table 2.2.

Default Base Address = 0x2A0

1

2

3

4

5

6

ON

A ( 9 8 7 6 5 4 )

Figure 2.2 Default Base Address Setting

I/O port address(hex)

1

A9

2

A8

3

A7

4

A6

5

A5

6

A4

200-20F

OFF ON ON ON ON ON

2A0-2AF

(*)

OFF ON OFF ON OFF ON

2B0-2BF

OFF ON OFF ON OFF OFF

3D0-3DF

OFF OFF OFF OFF ON OFF

3E0-3E0

OFF OFF OFF OFF OFF ON

3F0-3FF

OFF OFF OFF OFF OFF OFF

* Default setting

A9,...,A4 correspond to PC address lines