3 specifications – ADLINK ACL-7120A/6 User Manual
Page 9
Introduction
• 3
1.3 Specifications
♦
General Specification:
• Dimensions: 193.5 mm x 114 mm
• Bus: PC-AT bus
• I/O port address: Hex 200 - Hex 3FF
• Interrupt IRQ Level: IRQ3 - IRQ15
♦
Digital Input:
• Input logic low voltage: Min. -0.5V, Max. 0.8V
• Input logic high voltage: Min. 2.0V, Max. 5.0V
• Input loading current: Max. 0.2 mA at 0.4V
• Input hysteresis: Typical 0.4V, Min. 0.2V
♦
Digital Output:
• Output logic low voltage (Sink): Max. 0.5V at 24mA
• Output logic high voltage (Source): Min. 2V at –15mA
• Driving Capacity: All inputs and outputs are TTL/DTL compatible.
Outputs will drive 1 standard TTL load (74 series) or 4 LSTTL (74LS)
loads
• Input hysteresis: Typical 0.4V, Min. 0.2V
♦
Programmable Counter:
• Frequency: 4MHz
• Counter:
Device
Number of counters
ACL-7120A/3 3
ACL-7120A/6 4