ADLINK PXIS-2630 Series User Manual

Page 29

Advertising
background image

Specifications

23

A.3 APS-940XA PSU Specifications

AC Input Characteristics

VOLTAGE: 90 ~ 240 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 HZ.
INPUT CURRENT: 8.0 A (RMS) FOR 115VAC, 4.0 A (RMS) FOR

230VAC.

INRUSH CURRENT: 65A MAX. FOR 115 VAC, 125A MAX. FOR 230

VAC.

AC Input voltage is switching automatically according to AC input voltage.
The acceptable input voltage range is as following table.

Voltage

Frequency Minimum Maximum

Input Current

115 VAC

47 - 63Hz 90 VAC

130 VAC 8.0A (300W)

230 VAC

47 - 63Hz 180 VAC 260 VAC 4.0A (300W)

DC Output Characteristics

VDC

Minimum Maximum

Ripple and
Noise Max

Load
Regulation

Line
Regulation

+5 V

3.0 A

35 A

50 mV

±5%

±1%

+12 V

2.0 A

30 A

120 mV

+7%/-5%

±1%

-5 V

0 A

0.8 A

150 mV

±5%

±1%

-12 V

0 A

1.0 A

150 mV

±5%

±1%

+3.3 V 1.0 A

25 A

50 mV

±5%

±1%

+5Vsb

0.1 A

2 A

50 mV

±5%

±1%

REMARK: THE OUTPUT CURRENT OF 5V & 3.3V SHOULD NOT
EXCEED 45A.

SPECIFICATION:

Temperature range: Operating 0℃ --- 40℃.
Hold up time: 16 ms MINIMUM at full load & normal input voltage.
Dielectric Withstand: Input / Output 1500 VAC for 1 second.

Input to Frame Ground 1500 VAC for 1 second.

Efficiency: 68% Typical.
Power good signal: ON DELAY 100 ms to 500 ms, OFF DELAY 1 ms.
Over load protection: 130 +/- 20%.
Over voltage protection: +5V

Î 5.7V ~ 6.5V, 3.3V Î 3.9 ~ 4.3V, 12V Î

13.6 ~ 15V.

Short circuit protection: +5V, -5V, +12V, -12V, +3.3V.

Advertising