10 • Signal Connection

Signal Name

Type

Description

NO[15..0] Input/Output

Normally opened terminal of relays

NC[15..0] Input/Output

Normally

closed terminal of relays

COM[15..0] Input/Output

Common terminal of relays

AUX[7..0] Input/Output

Programmable Digital I/O with tri-state
control.
AUX[2..0] are dual function pins used for
triggering, refer to chapter 4 for details.

TRG_IN

Input

Trigger input for handshaking operation

S_ADV Output

Scanner Advanced trigger output for
handshaking operation

SHDNn

Input

Active-low Emergency Shutdown trigger

+5V out

Output

Unregulated +5V DC Source, maximum
100mA current loading

GND Output

Ground

NC

Not Connected Unused pin

Table 2: Pin Description

3.3 TB-6201 Terminal Board

The TB-6201 is a screw terminal board with D-sub 62-pin female connector.
The terminal board can attach to PXI-7901 directly, or through ADLINK custom-
made high-capacity 62-pin D-sub cable.
The pin description is described in Table 2.