Introduction – ADLINK PXI-7901 User Manual

Page 7

Advertising
background image

Introduction • 1

1


Introduction

ADLINK PXI-7901 is a general-purpose (GP) switch module implementing 16-
CH independent single-pole double-throw (SPDT) relays (1 Form C). PXI-7901
can connect one input to one output, and be used as signal switching or routing
for measurement systems as well as ATE.

Relays of PXI-7901 can be updated by either direct-update mode or auto-scan
mode. The latter mode supports scanlist of 1k-sample for deterministic
scanning.

PXI trigger functions are fully supported and software programmable. The
multiple switch modules can be synchronized and triggered without additional
field wiring.

For safety critical applications, PXI-7901 module can switch to the preset state
by either asserting emergency shutdown manually, or watchdog timer overflow
event.

1.1 Features

PXI specifications Rev. 2.0 compliant

3U Eurocard form factor, CompactPCI compliant (PICMG 2.0 R3.0)

PICMG 2.1 R2.0 CompactPCI Hot-Swap

specifications compliant

16-CH SPDT (1 Form C) non-latching relays

• Contact

rating

3A switching, 3A carrying

• 220V

DC

, 250V

AC

125 operations per second

1k-sample scanlist for deterministic scanning

Provides handshaking signals to trigger external instruments

Programmable emergency shutdown function and Watchdog timer for
safety critical applications

Eight auxiliary 3.3 V/TTL digital inputs/outputs with 5V tolerance

Supports PXI backplane triggers to synchronize multiple modules

• Fully

software

programmable

Advertising