5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information in column 1. If you don’t

smell gas, go to the next step.

6. The pilot is located by the main burner and

should not require accessing for lighting.

7. Turn gas control knob counterclockwise

to PILOT.

8. Push in gas control knob all the way and

hold. Immediately light pilot by repeatedly

depressing piezo spark ignitor until a flame

appears. Continue to hold for about 1 min-

ute after pilot is lit. Release gas control knob

and it will pop back. Pilot should remain

lit. If it goes out, repeat steps 4 through 7.

• If gas control knob does not pop up when

released, stop and immediately call our

service technician or gas supplier.

• If pilot will not stay lit after several tries,

turn gas control knb to OFF and call your

service technician or gas supplier.

9. Turn on all electric power to the fireplace.

10. Turn gas control knob counterclockwise

to ON.

11. This valve is equipped with a HI/LO fea-

ture. Set fireplace input as desired.

12. Close lower louver panel.

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance is equipped with an ignition

device which automatically lights the pilot.

Do not try to light by hand.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier

from a neighbor's phone. Follow the gas

supplier's instructions.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the

knob will not push in or turn by hand,

don't try to repair it, call a qualified service

technician. Force or attempted repair may

result in a fire or explosion.

D. Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of

new heater, burning logs will give

off a paper-burning smell. Orange

flame will also be present. Open

damper or window to vent smell.

This will only last a few hours.

1. STOP! Read the safety information,

above.

2. Open lower louver panel.

3. Turn off all electric power to the fireplace.

4. Push in gas control knob slightly and turn

clockwise

to OFF.

TO TURN OFF GAS

TO AppLIANCE

1. Open lower louver panel.

2. Set selector switch in the OFF position to

prevent draining battery.

3. Turn off all electrical power to the appliance

if service is to be performed.

4. Push in gas control knob slightly and turn

clockwise

to OFF.

5. Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot

lit by doing one of the following:
1. Turn gas control knob clockwise

to the PILOT position.

2. Set selector switch in the OFF position.

O

F

F

PILOT

LO

IH

O

N

Figure 50 - Control Valve

Piezo
Ignitor

Gas Control
Knob

Variable Control Knob