ADLINK cBP-3204[R] User Manual
Page 23
 
Power Supply Unit
• 13
meets EN55022 Class A
EMS:EN 50082-2
EN61000-4-2 
EN61000-4-3 
EN61000-4-4 
EN61000-4-6 
EN61000-4-8 
ENV 50204 
Impact & vibration 
test 
Frequency Range: 
5Hz – 35Hz 5 min 
35Hz – 55Hz 5 min 
55Hz – 5Hz 5 min 
Displacement: 0.38mm 
Dweep time: 30 minutes for each axis 
Duration: 2 cycles for three orthogonal 
axis. Axis: X, Y, Z 
Unpackaged, 
Non-operating 
Insulating strength
Primary - secondary: 4242Vrms 
Primary - chassis ground: 3050Vrms 
secondary - chassis ground: 500Vrms 
Output insulation
Relatively to chassis ground, all 
control signals and outputs are 
floating SELV circuits. 
Operation 
temperature 
0°C~70°C(the temperature on the 
chassis) 
Full power from 0°C to 40°C with 15 
cfm forced air flow 
Storing temperature
−
40°C to +85°C
Relative humidity
<95% @ 40°C, none condensation
Operation height
6,400m
Weight
about 0.85Kg
Figure 3.1.4 Working Area
0 10 20 30 40 50 60 70
Ambient °C
100
50
0
forced air 15 cfm