• Power Supply Unit

Operating temperature: 0°C to 70°C

When the ambient temperature is over 40°C (115V/230V) , the
output power should be de-rated as following curve:

Storage temperature: -40°C to +75°C

Operating humidity: The power supply can operate from 5%
humidity to 95% humidity non-condensing at 40°C

u

Regulatory Agency Certification

Safety standards: Designed to meet the following standards:

UL 1950
CSA 22.2 NO.234
EN 60950

EMI standards: Designed to meet the following radiated limits:

FCC class “B”
EN55022 class ”B”

EMS standards: Designed to meet the following standards:

IEC-801-2 8KV air discharge
IEC-801-3 3V/M
IEC-801-4 2KV
IEC-801-5 2KV

u

ATX Power Connector definition

Signal

Pin No. Pin No.

Signal

+3.3V

1

11

+3.3V

+3.3V

2

12

-12V

GND

3

13

GND

+5V

4

14

PS_ON

GND

5

15

GND

+5V

6

16

GND

GND

7

17

GND

PWR_OK

8*

18

-5V

+5V SB

9*

19

+5V Sense

+12V

10

20

+5V