4 specifications – ADLINK cBP-3204[R] User Manual

Page 28

Advertising
background image

18

• Power Supply Unit

There are two external warning LEDs.

POWER: The Power LED is lit green if the AC or DC external power input
power has been turned on.

FAULT: If LED is with light, it indicates that the power unit is defective. It
means the input voltage is out of the range, or over temperature, over current,
or short circuit.

3.2.4

Specifications

Input

Item

cPS-175/AC

cPS-175/48

cPS-175/24

Voltage

90 – 264 Vac

36 – 72 V

DC

18 - 36 V

DC

Input Current

<5A

<9A

<20A

Inrush Current

<40A @ 240V AC

<40A

<40A

Frequency

50 – 60 Hz

Power Factor

0.99 typical

Efficiency

Typical 73%

Typical 73%

Typical 73%

Protection

Fuse, Over Voltage,
Under Voltage, Surge
Protection
Note:
Current = 5A max.
Voltage: 270 Vmax
85Vmin.

Fuse, Over Voltage,
Under Voltage, Surge
Protection
Note:
Current = 10A max.
Voltage: 75 Vmax.
35 Vmin.

Fuse, Over Voltage,
Under Voltage, Surge
Protection
Note:
Current = 20 A max.
Voltage: 40 Vmax.
16 Vmin.

Output

Item

cPS-175/AC

cPS-175/48

cPS-175/24

Rated Power

175W maximum

175W maximum

175W maximum

Voltage

+5V, +3.3V, +12V, -12V

Current

25A @ +5V

*1

25A @ +3.3V
3A @ +12V
1A @ -12V
Combined current @ +5V & +3.3V < 27A

Voltage Error

<

±

3% @ +5V

<

±

5% @ +3.3V

<

±

5% @ +12V

<

±

5% @ -12V

Ripple Voltage

100mV or 1 % whichever is greater

Current Sharing Any number of power supplies can be operated in parallel and will

share +5V and +3.3V current to within 10%.

Load regulation

±

1%@+5V

±

3%@+3.3V / +12 V / -12V

Line regulation

±

0.3%

Hold-up time

> 6ms

Rise time

< 500ms from AC/DC power up. All output voltages come up within 10
msec of each other.

Advertising