ADLINK cBP-3204[R] User Manual

Page 53

Advertising
background image

Backplane

• 43

u

CN104 extended connector for power sharing

Signal

Pin No. Pin No.

Signal

V2SENSE

1

11

V2

V2

2

12

V4

GND

3

13

GND

V1

4

14

INH#

GND

5

15

GND

V1

6

16

SRTN

GND

7

17

GND

FAL#2

8*

18*

V3SENSE

DEG#2

9*

19

V1SENSE

V3

10

20

V1

Note: 1. Pin #8, #9, and #18 are not standard ATX power definition.
2. V1=+5V; V2= 3.3V; V3 = +12V; V4=-12V

u

CN105 INH#: DC power output inhibit signal. It is for inhibiting the DC

power supply. This connector can be used for power-on switch.

Pin #

Name

1

INH#

CN105

2

GND

u

CN107: Screw terminals for external AC input power lines

u

CN106: Current sharing connector, this connector is used only when

multiple power backplane is used in the same time.

Signal

Pin No. Pin No.

Signal

V1SENSE

1

2

V3SENSE

GND

3

4

V2SENSE

GA2#2

5

6

GA2#1

GA1#2

7

8

GA1#1

GA0#2

9

10

GA0#1

N/C

11

12

N/C

Advertising