3.3.3. LVDS

Signal

Pin

Description

I/O

PU/PD

Comment

LVDS_A0+
LVDS_A0-
LVDS_A1+
LVDS_A1-
LVDS_A2+
LVDS_A2-
LVDS_A3+
LVDS_A3-

A71
A72
A73
A74
A75
A76
A78
A79

LVDS Channel A differential pairs

O LVDS

LVDS_A_CK+
LVDS_A_CK-

A81
A82

LVDS Channel A differential clock

O LVDS

LVDS_B0+
LVDS_B0-
LVDS_B1+
LVDS_B1-
LVDS_B2+
LVDS_B2-
LVDS_B3+
LVDS_B3-

B71
B72
B73
B74
B75
B76
B77
B78

LVDS Channel B differential pairs

O LVDS

LVDS_B_CK+
LVDS_B_CK-

B81
B82

LVDS Channel B differential clock

O LVDS

LVDS_VDD_EN

A77

LVDS panel power enable

O 3.3V

LVDS_BKLT_EN

B79

LVDS panel backlight enable

O 3.3V

LVDS_BKLT_CTRL

B83

LVDS panel backlight brightness control

O 3.3V

LVDS_I2C_CK

A83

DDC lines used for flat panel detection and control.

O 3.3V

PU 2k2 3.3V

LVDS_I2C_DAT

A84

DDC lines used for flat panel detection and control.

I/O 3.3V

PU 2k2 3.3V

3.3.4. Gigabit Ethernet

Gigabit Ethernet

Pin

Description

I/O

PU/PD

Comment

GBE0_MDI0+
GBE0_MDI0-
GBE0_MDI1+
GBE0_MDI1-
GBE0_MDI2+
GBE0_MDI2-
GBE0_MDI3+
GBE0_MDI3-

A13
A12
A10
A9
A7
A6
A3
A2

Gigabit Ethernet Controller 0: Media Dependent Interface Differential
Pairs 0, 1, 2, 3. The MDI can operate in 1000, 100, and 10Mbit/sec
modes. Some pairs are unused in some modes, as described here:
1000BASE-T

100BASE-TX

10BASE-T

MDI[0]+/- B1_DA+/-

TX+/-

TX+/-

MDI[1]+/- B1_DB+/-

RX+/-

RX+/-

MDI[2]+/- B1_DC+/-
MDI[3]+/- B1_DD+/-

I/O Analog

Twisted pair
signals for
external
transformer.

GBE0_ACT#

B2

Gigabit Ethernet Controller 0 activity indicator, active low.

OD 3.3VSB

PU 1k
3.3V

GBE0_LINK#

A8

Gigabit Ethernet Controller 0 link indicator, active low.

OD 3.3VSB

GBE0_LINK100#

A4

Gigabit Ethernet Controller 0 100Mbit/sec link indicator, active low.

OD 3.3VSB

GBE0_LINK1000#

A5

Gigabit Ethernet Controller 0 1000Mbit/sec link indicator, active low.

OD 3.3VSB

GBE0_CTREF

A14

Reference voltage for Carrier Board Ethernet channel 1 and 2
magnetics center tap. The reference voltage is determined by the
requirements of the Module PHY and may be as low as 0V and as high
as 3.3V. The reference voltage output shall be current limited on the
Module. Where the reference is shorted to ground, the current shall be
250 mA or less.