19 power jumper settings, Jpy1: at/atx mode, Cny6: pwr_ok config cny7: power up config – ADLINK Express-BASE User Manual

Page 32: Jpy10: ps_on# signal source, Jpz3: at power 5v setting

Advertising
background image

Express-BASE User’s Manual

Page 32

JPY1:

AT/ATX MODE

In AT mode, JPY1 shorts PS_ON# to ground
directly to force power on.

Jumper

Status

1-2

ATX Mode

<<<<

2-3

AT Mode

1
2
3

CNY6:

PWR_OK Config

CNY7:

Power Up Config

Jumper

Status

1-10
5-6

Power-up by module

<<<<

8-9
2-9
3-8

Power-up by Super I/O*

4-7

5

10

1

6

Jumper

Status

1-2

Add 3.3V Pullup with 10K to signal PWR_OK

3-4

Connect PWRGOOD of ATX power supply

<<<<

5-6

Connect PWRGOOD of onboard DCDC regulator

*The Super I/O detects a power button event using the 'PSIN' pin. When a power button event occurs, the power-
up logic of the Super I/O sets 'PSOUT#' low and asserts 'PWRBTN#' of the module's chipset. The Super I/O also
sets the 'PWRCTL#' pin to low, which asserts the 'PS_ON#' signal and switches on the ATX power supply.

NOTE:

<<<< indicates default setting

6.19 Power Jumper Settings

JPY10: PS_ON# Signal Source

Jumper

Status

1-2

SUS_S3#

<<<<

2-3

SUS_S5#

1
2
3

All ADLINK modules support S3 mode and
consecutive power down of ATX power supply.
For modules that connect the S3 signal, PS_ON#
should always be set to SUS_S3# as source (even when S3 mode is disabled in the BIOS). For
modules that do not bring out the S3 signal, PS_ON# should be set to SUS_S5# as source.

JPZ3:

AT Power 5V Setting

With an AT power supply is connected to
the Express-BASE, JPZ3 can be used to
provide 5VSB to the COM module from
the carrier board.

Jumper

Status

1-2

AT without P5V

<<<<

2-3

AT with P5V

1
2
3