JPY11: Ethernet Mode

Configure the jumper to "10/100/1000" for
modules with Gigabit Ethernet, to "10/100" for
modules with Fast Ethernet

Jumper

Status

1-2

10/100/1000 <<<<

2-3

10/100

1
2
3

JPY7, JPY8: Reserved

JPA1:

Super I/O

Enables/disables the Super IO. By default, the
Express-BASE enables the onboard W83627HG-
AW Super I/O. To disable the Onboard Super I/O,
short pins 2-3 of Jumper JPA1.

Jumper

Status

1-2

Enable

<<<<

2-3

Disable