Specifications – ADLINK CM1-86DX2 User Manual

Page 11

Advertising
background image

Introduction

5

CM1-86DX2

1.5 Specifications

Electrical Specifications

Environmental Specifications

Table 1-3: Electrical Specifications

Supply voltage:

+5 V DC

+5 V standby (only needed for suspend mode)

+12 V (only needed for LVDS display and expansion
slots)

Rise time:

< 10 ms

Supply voltage tolerance:

± 5%

Inrush current:

1.6 A

Supply current:

max. 1.7 A (Windows XP, PIcalc [lots of decimals of
PI]) ; typical 1.5A

Table 1-4: Operating

Temperature range

0°C … 60°C (standard version)

-20°C … 60°C (industrial version)

-40°C … 85°C (extended version)

Temperature change

max. 10 Kelvin per 30 minutes

Humidity (relative)

10 % … 90 % (non-condensing)

Pressure

450 hPa … 1100 hPa

Table 1-5: Non-Operating/Storage/Transport

Temperature range

-40°C … 85°C

Temperature change

max. 10 Kelvin per 30 minutes

Humidity (relative)

5 % … 95 % (non-condensing)

Pressure

450 hPa … 1100 hPa

Table 1-6: HALT Parameters

Cold Temperature Step Stress

The board remained operational during test down to
-100°C, starting at +20°C and decreasing in 10°C
increments with 15 minute dwells

Hot Temperature Step Stress

The board remained operational during test up to
+90°C, starting at +30°C and increasing in 10°C incre-
ments with 15 minute dwells

Rapid Thermal Transitions

The board was subject to five rapid temperature cycles
from -90°C to +85°C @ set transition rate of 60°C per
minute

Advertising