Module Description

3.10 LPT Interface (X19)

The parallel port is located on an IC26 header. An adapter cable with standard DSUB-25 female
connector is available. The parallel port is programmable in BIOS. Enter ADVANCED>CHIP-
SET>Southbridge Configuration>Serial/Parallel Port Configuration for access to the following
settings.

LPT Header (X19)

Connector type: IDC26 pin header, 2.54 mm (X19)

Matching connector: IDC26 pin female connector, 2.54 mm

Table 3-19: BMC Service Connector (X24)

LPT Parameter

Possible Settings

Base Address

Disabled, 0x378 and 0x278

Mode

BPP, EPP 1.9 and SPP, ECP, ECP and EPP 1.9, SPP, EPP 1.7 and SPP, ECP
and EPP 1.7

IRQ

Disabled, IRQ 3, IRQ 4, IRQ 5, IRQ 6, IRQ 7, IRQ 9, IRQ 10, IRQ 11, IRQ 12,
IRQ 14 and IRQ15

Table 3-20: LPT Header Signals (X19)

Pin

Signal

Pin

Signal

1

Strobe

2

Auto LF

3

Data0

4

Error

5

Data1

6

Init

7

Data2

8

Select In

9

Data3

10

GND

11

Data4

12

GND

13

Data5

14

GND

15

Data6

16

GND

17

Data7

18

GND

19

ACK

20

GND

21

busy

22

GND

23

Paper End

24

GND

25

Select

26

+5.0 Volt

The maximum current on all supply pins is 0.5A.