Section 3 – Installation

Dukane Manual Part No. 403-573-02

Connecting Cables

Standard Model Configuration

Complete three basic connections for the standard con-
figuration as shown below:

AC Line Input

System Control Inputs/Status Outputs

Ultrasound Output

Grounding

Details about the various system connectors and their pin
assignments are covered in the next section.
Step 1. Wire the AC line connector, and attach it to the

generator’s power inlet connector, matching the
power source line, ground, and neutral with the
generator’s line, ground, and neutral connector
pins -

A

in Figure 3–1. (See Figure 2-1 also.)

Step 2. Wire the user-supplied automation system control

inputs/status outputs to the CONTROL CON-
NECTOR, and attach it to the system I/O port -

B

in Figure 3-1.

Step 3. Attach a high–voltage coaxial ultrasound cable

(from the ultrasonic probe) to J1, the ultrasound
output connector -

C

in Figure 3-1.

Step 4. Connect the included ground wire from the ground-

ing stud,

D

in Figure 3-1, to earth ground.

Figure 3-1

Generator Front View - Standard Model

NOTE

AC Power Inlet

Line voltage required for the generator is
200-240 VAC at 50/60 Hertz and 6.3 Amps,
or 100-120VAC at 50/60 Hz and 15 Amps.
The unit does not include a power switch,
and is powered ON whenever the AC line
power is live.
The unit can be switched ON/OFF with a
user-supplied AC circuit breaker wired to
the AC power inlet connection.

NOTE

Connecting Cables

Two-piece pluggable terminal block connec-
tors are used for the System I/O connections
and the AC Power Inlet connections.
This type of connector allows the wiring to
be attached to the screw terminal connec-
tor, which plugs into the mating connector
on the iQ Auto system front panel.
In the event a field replacement unit is re-
quired, the screw terminal connectors with
the wires can be easily detached and then
plugged into the replacement unit.

LOWER REAR
MOUNTING BRACKET

BASE MOUNTING

BRACKETS(2)

2.00
[50.8]

2.00
[50.8]

.75
[19.05]

3.35
[85.09]

3.47
[88.14]

9.38
[238.25]

POWER INLET

CONTROL

CONNECTOR

U/S CONNECTOR

U/S

SYSTEM I/O

POWER

STATUS (LED)

10.76
[273.30]

IN
[ mm ]









TOP REAR

MOUNTING BRACKET

GROUNDING STUD

AMPLITUDE

20%

100%

AMPLITUDE
ADJUSTMENT
CONTROL

See NOTE on
Page 22 .

Advertising