Optional mpc interface connections – Dukane ULTRASONIC GENERATOR/POWER SUPPLY 403-573-02 User Manual

Page 26

Advertising
background image

Page  20 

iQ Series,

 Auto User’s Manual

Dukane Manual Part No. 403-573-02

Optional MPC Interface Connections

Complete the same basic connections used for the stan-
dard iQ Auto configuration as previously described.

AC Line Input

System Control Inputs/Status Outputs

Ultrasound Output

Grounding (optional)

In addition to completing Steps 1- 4 of the basic con-
nections as previously described, complete Steps 5 and
6 to wire the MPC Control Inputs/Status Outputs as
described below.

Figure 3-2 Generator Front View - Optional MPC Model

Optional Multi- Probe Control
(MPC) Interface Model

The iQ Auto MPC model includes an optional MPC
Interface circuit board that powers and controls an external
MPC multi- probe control module. This external module,
(that can be ordered with a minimum of two probe controls
up to a maximum of 16 probe controls), must be purchased
in addition to generator Model 40AT060-2N-MO (iQ Auto
with MPC option) for a fully functional MPC system.
The connections needed for the MPC Interface board are
described below. Connections required for the external
MPC module are also described below.

Details about the various system connectors and their
pin assignments are covered in the next section.

Step 5.

MPC I/O

- Wire the MPC control/input signals

and status output signals terminal block to the
user-supplied automation control system -

E

in Figure 3-2.

Step 6. MPC INTERFACE - Attach one end of the MPC

Interface cable (Dukane # 200-1408-XX) to the
MPC Interface connector on the iQ Auto panel
-

F

in Figure 3-2. Connect the other end of the

cable to the MPC INTERFACE connector on
the right rear of the MPC module.

NOTE

The MPC Interface cable is a separate line
item on the iQ Auto system order. The -XX
at the end of the cable number specifies
cable length. This will vary depending on
your MPC installation.

POWER INLET

CONTROL

CONNECTOR

U/S CONNECTOR

U/S

SYSTEM I/O

OPTIONAL MPC
CONNECTORS

POWER

STATUS (LED)

MPC I/O

MPC INTERFACE





GROUNDING STUD

AMPLITUDE

20%

100%

AMPLITUDE
ADJUSTMENT
CONTROL

See NOTE
on Page 22 .

NOTE

Amplitude adjustment will affect ALL
MPC points.

Advertising