Section 3 – Installation
Dukane Manual Part No. 403-573-02
Pin 1
(Enable Out)
This is a current limited voltage source output intended 
to connect to an E-Stop circuit. If an E-Stop circuit is 
not used, Pin 1 must be jumpered to Pin 2 for ultrasound 
operation to be enabled.
Pin 2
(Enable In)
The output from the E-Stop circuit is connected to this 
pin when an E-Stop circuit is used. Otherwise, this pin 
must be jumpered to Pin 1 for ultrasound operation to 
be enabled. See Figure 6-4 for E-Stop circuit wiring 
examples.
Pin 3
(Overload Out)
Pin 3 is a non-isolated digital NPN status output that 
activates when an output overload condition is tripped. 
This output will be an open circuit if an output overload 
condition is not tripped. This output will remain latched 
ON until the U/S Activate input is switched OFF and 
then ON again. 
Pin 4
(Ultrasound Active Status Output)
Pin 4 is a non-isolated digital NPN status output that 
activates when the system is delivering ultrasonic power 
to the load attached to the ultrasound output connector. 
This output will be an open circuit when the ultrasound 
output is off.
Pin 5
(Any Fault Out)
Pin 5 is a non-isolated digital NPN status output that 
activates whenever any fault condition is detected that 
inhibits ultrasound output and normal system operation. 
This output will be an open circuit when no system fault 
conditions are active.
Pin 6
(Power OK Out)
Pin 6 is a non-isolated digital NPN status output that 
activates when no fault conditions are detected by any of 
the power fault detection circuits included in the system. 
This output will be an open circuit when any power 
related fault condition is detected.
Pin 7
(Output Common)
Pin 7 is connected to chassis ground. The non-isolated 
NPN status output signals can drive isolated PNP inputs 
on the automation control system. Refer to Section 6 for 
wiring examples to connect output signals.
Pin 8
(Spare Status Out)
Pin 8 is not functional with the standard factory 
configuration. 
Pin 9
(Analog Power Out +)
Pin 9 is a analog output signal proportional to the true 
RMS ultrasound power output level. This signal is 
scaled so 1mV = 1 Watt.
Pin 10
(Analog Power Out -)
Pin 10 is a signal ground (non-isolated chassis ground) 
for the Analog Power output signal on Pin 9.
Pin 11
(Fault Reset Input)
Pin 11 is an isolated input control signal that will reset 
any output faults when it is activated. It can be used 
by the automation control system to simplify PLC 
programming. 
Pin 12
(U/S Activate Input)
Pin 12 is used to activate the generator ultrasound 
output. Activating this isolated control input will switch 
the ultrasound output ON, and deactivating this signal 
will switch ultrasound OFF. 
Pin 13
(Input Common)
[Electrically connected to Pin 5 on MPC I/O connector 
if MPC Interface option is installed.]
Pin 13 is electrically isolated from chassis ground. 
Using sourcing (PNP) output drivers, this common line 
would be connected to the automation system power 
supply common. Using sinking (NPN) output drivers, 
this common line would be connected to the automation 
system positive supply output. Refer to Section 6 for 
wiring examples to connect these input signals.