Five fault conditions are monitored by the iQ
Auto system for Any Fault:

Average Overload

(Automatically resets on next cycle, or until an
activation of Fault Reset Input)

Peak Overload

(Resets same as Average Overload)

Overtemperature

(Automatically resets on cool-down)

Power Not OK

(AC line voltage under 180VAC)

Frequency Overload

(Automatically resets on next cycle, or until an
activation of Fault Reset Input)

iQ

Auto System with MPC

Operational Test

Step 1. Verify that the system installation (with the MPC

option) is completed and all cables are connect-
ed.

Refer to the iQ Auto installation instructions in
Section 3, if needed.

Refer to Section 6 - Automation Interface - for in-
formation on wiring system controls, if needed.

Step 2. After completing Step 1, activate line power to the

standard iQ Auto system.

Normal Condition:

The POWER STATUS

LED

on the iQ Auto front

panel should light up GREEN.

The MPC module SYSTEM STATUS

LED

should

light up GREEN.

The system is ready to operate when both status

LED

s

light up GREEN.

Troubleshooting Abnormal iQ Auto Sys-
tem Conditions

RED - If the POWER STATUS

LED

lights

up RED, check line voltage level.

GRAY - If the POWER STATUS

LED

is a

gray color (not lit), check line input.

Troubleshooting Abnormal MPC Module
Conditions

MPC Module

SYSTEM STATUS

LED

is

ORANGE/YELLOW

(resettable fault):

Check for an iQ Auto overload on the previous

welding cycle.

Check for an invalid channel selection input

control code - selection code is greater than the
number of installed channels.

MPC SYSTEM STATUS

LED

is RED (non-recov-

erable fault.

Check for POWER OK fault on the iQ Auto Sys-
tem.

Resolve any iQ Auto power problem first.

There could be a circuit failure in the MPC

module. If a circuit failure is discovered, return
the MPC Module to Dukane for service
.

Step 3. After completing Step 2, test ultrasound output

by activating I/O Connector Pin 12.

Normal Condition:

The system is operating properly when power is
delivered to the attached stack.

Ultrasound Activation Connections

:

Usually an automated control system is wired
to this control input.

Optionally - A manual switch could be wired
to this control input.

Continued

Continued from previoius page