Mpc probe control, Ultrasound output connector – Dukane ULTRASONIC GENERATOR/POWER SUPPLY 403-573-02 User Manual

Page 28

Advertising
background image

Page  22 

iQ Series,

 Auto User’s Manual

Dukane Manual Part No. 403-573-02

NOTE

Ultrasound Output Connector

The ultrasound output connector
used with all standard generators is
a high voltage (5000V) coaxial style
SHV-BNC connector. This connector
provides superior shielding of electri-
cal noise, compared to other types
of connectors. The ultrasound output
connector mates with fully shielded
coaxial ultrasound cables that are
secured with a simple and reliable
quarter-turn bayonet style attachment
mechanism.

The ultrasonic output from this con-
nector (that drives the attached
ultrasonic load) is a very high AC volt-
age (1200VAC). At high power levels
this can exceed 2 amps of current and
must be securely terminated via the
ultrasound cable for safe operation.
Use original equipment ultrasound
cables for safe and reliable system
operation. Improperly assembled
ultrasound cables can result in high
voltage arcing and will destroy the
ultrasound connectors.

MPC Probe Control

When the optional MPC Interface and MPC I/O
connectors are used, the generator has the capability of
controlling as many as sixteen compatible probes. One
probe can be turned on at a time while the sequence
of probe activation is determined by the user’s
automation.

The table below shows how the setup bit inputs
correspond to the probes.

MPC

Probe

Selected

3

2

1

0

Off

Off

Off Off

1

Off

Off

Off On

2

Off

Off

On Off

3

Off

Off

On On

4

Off

On Off Off

5

Off

On Off On

6

Off

On On Off

7

Off

On On On

8

On

Off

Off Off

9

On

Off

Off On

10

On

Off

On Off

11

On

Off

On On

12

On

On Off Off

13

On

On Off On

14

On

On On Off

15

On

On On On

16

Table 3-III MPC Setup Bit Inputs