Dahua Technology LE-L User Manual

Page 34

Advertising
background image

34

Figure 3-6

In the first line, from
the left to the right,:
1,2,3,4,5,
6,7,8,9,10,
11,12,13,14,
15,16

ALARM 1 to ALARM 16. The alarm becomes active in low voltage.

In the second line,
from the left to the
right:
NO1 C1,
NO2 C2,
NO3 C3,
NO4 C4,
NO5 C5 NC5

The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)

CTRL 12V

Control power output. You need to close the device power to cancel
the alarm.

+12V

It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).

Earth cable.

485 A/B

485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120TΩ between A/B cables if there are
too many PTZ decoders.T

2 HDD Series
Please refer to the following sheet and figure 3-7 for detailed information.

Figure 3-7