Dahua Technology LE-L User Manual

Page 35

Advertising
background image

35

In the second line,
from the left to the
right,: 1,2,3,4,
5,6,7,8,
In the first line, from
the left to the right:
9,10,11,12,
13,14,15,16

ALARM 1 to ALARM 16. The alarm becomes active in low voltage.

In the second line,
from the left to the
right:
NO1 C1,
NO2 C2,
In the first line, the
NO3 C3

The three groups of normal open activation outputs(on/off button)

Earth cable.

485 A/B

485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120TΩ between A/B cables if there are
too many PTZ decoders.

3.8.2 Alarm Input Port

Please refer to the following sheet for more information.
z

4/8/16-ch grounding alarm inputs. (Normal open or Normal close type)

z

Please parallel connect COM end and GND end of the alarm detector (Provide external

power to the alarm detector).

z

Use the controllable +12V power to reset the smoke sensor remotely.

z

Please parallel connect the Ground of the DVR and the ground of the alarm detector.

z

Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)

z

Use the same ground with that of DVR if you use external power to the alarm device.

Figure 3-8

3.8.3 Alarm Output Port

z

The 4 HDD series DVR has 6 ways relay alarm outputs and the 2 HDD series DVR has 3

ways relay alarm outputs. (NO contact). Provide external power to external alarm device.

z

To avoid overloading, please read the following relay parameters sheet carefully.

z

For controllable +12V, it can be used to provide power to devices such as reset smoke

sensor.

z

RS485 A/B cable is for the A/B cable of the PTZ decoder.