6 alarm setup and alarm activation – Dahua Technology LE-L User Manual

Page 54

Advertising
background image

54

Figure 4-25

4.6 Alarm Setup and Alarm Activation

Before operation, please make sure you have properly connected alarm devices such as
buzzer.

4.6.1 Go to alarm setup interface

In the main menu, from Setting to Alarm, you can see alarm setup interface. See

X313H313H313H

Figure 4-26.

4.6.2 Alarm

setup

Alarm interface is shown as below. See

X313H313H313H

Figure 4-26.

z

Alarm in: Here is for you to select channel number.

z

Event type: There are two types. One is local input and the other is network input.

z

Type: normal open or normal close.

z

PTZ activation: Here you can set PTZ movement when alarm occurs. Such as go to preset,

tour& pattern when there is an alarm. Click “select” button, you can see an interface is
shown as in

X315H315H315H

Figure 4-27

X

.

z

Period: Click set button, you can see an interface is shown as in

X316H316H316H

Figure 4-28

X

. Here you can

set for business day and non-business day. In

X317H317H317H

Figure 4-28

X

, click set button, you can see an

interface is shown as in

X318H318H318H

Figure 4-29

X

. Here you can set your own setup for business day and

non-business day.

z

Anti-dither:

Here

you

can set anti-dither time.

z

Show message: System can pop up a message to alarm you in the local host screen if you

enabled this function.

z

Alarm upload: System can upload the alarm signal to the network (including alarm centre)

if you enabled current function.

z

Send email: System can send out email to alert you when alarm occurs.

z

Record channel: you can select proper channel to record alarm video (Multiple choices). At

the same time you need to set alarm record in schedule interface (Main Menu->Setting-
>Schedule) and select schedule record in manual record interface (Main Menu->Advance-
>Manual Record).

z

Latch: Here is for you to set proper delay duration. Value ranges from 10 to 300 seconds.

System automatically delays specified seconds in turning off alarm and activated output after
external alarm cancelled.

z

Tour: Here you can enable tour function when alarm occurs. System supports one-window

tour. Please go to chapter 5.3.9 Display for tour interval setup.

z

Video output: Once you enable this function, the selected alarm channel will be displayed in

video output channel.

For snapshot operation, please refer to chapter 4.4.2.

Please highlight icon

to select the corresponding function. After setting all the setups

please click save button, system goes back to the previous menu.

Advertising