Error analysis – EXFO FTB-8100 Series Transport Blazer for FTB-200 User Manual
Page 344

10G Ethernet Tabs
332
FTB-8100 Series Transport Blazer
Error/Alarm RX
Error Analysis
³
FCS: The number of received frames with an invalid FCS.
³
Jabber/Giant: The number of received frames larger than 1518 (no
VLAN tag), or 1522 (1 VLAN tag) bytes with an invalid FCS.
³
Oversize: The number of received frames larger than 1518 (no VLAN
tag), or 1522 (1 VLAN tag) bytes with a valid FCS. Oversize error
analysis is only available when Oversize Monitoring is enabled (see
page 331).
³
Runt: The number of received frames that are smaller than 64 bytes
with an invalid FCS.
³
Undersize: The number of received frames smaller than 64 bytes with
a valid FCS.
³
Block: The number of frames received with an errored block
condition.
Total Error Count: Indicates the total number of errors including all the
above errors at the exception of Oversize when the Oversize Monitoring
check box is not selected.