EXFO FTB-8100 Series Transport Blazer for FTB-200 User Manual
Page 69

Creating and Starting a Test Case
SONET/SDH Application
57
Typical Test Cases
2. Press the Port node.
2a. Press More to see all available interfaces and press the desired
interface: DS3, DS1, E4, E3, E2, or E1.
2b. For DS1/E1, select the connector
type: BNC (E1 only), Bantam, or
RJ-48C.
2c. Select the Line Coding, LBO (DSn
interface only), and Termination
Mode. Term, Mon, and Bridge
(DS1/E1 only) termination mode
are available. For more information, refer to Port TX (Electrical
Interfaces) on page 114 for Line Coding and LBO, to RX - DSn Tabs
on page 213 or PDH Tabs on page 301 for Termination Mode.
3. Press the Mapping node.
3a. Select the mapping.
Choices depend on
the selected interface.
See Supported
Paths/Mappings on
page 51 for more
information.
3b. Select the Framing.
For more information,
refer to DSn Tabs on
page 213 or PDH Tabs
on page 301.
3c. For DS3, select the
Enable FEAC check
box to allow far end
alarm and control testing.
3d. Select the Channel number(s) of the selected mapping.