Cfp/cfp2 control pins, Cfp/cfp2 status pins – EXFO FTB/IQS-85100G Packet Blazer for FTB-500/IQS-600 User Manual
Page 264

Test Functions
254
FTB/IQS-85100G
40/100G Advanced - CFP/CFP2 Control
CFP/CFP2 Control Pins
Allows the following CFP/CFP2 control pin settings. Refer to the CFP MSA
standard for more information.
Note: To apply any control, first select its check box then clear it; the control is
applied only when the selected check box is cleared.
TX & RX IC RST check box (cleared by default).
Connector Power Rating, choices are:
TX Disable check box (cleared by default).
Module Low Power Mode check box (cleared by default).
Module Reset check box (cleared by default).
Module Power Shutdown check box (cleared by default).
CFP/CFP2 Status Pins
Gives the following CFP’s pin status: Hi Power On, Module Ready, Module
Fault, Module Absent, RX Loss of Signal, and Global Alarm. Refer to the
CFP MSA standard for more information.
Connector
Power Rating
CFP
Power Class 1 (<= 8W)
Power Class 2 (<= 16W)
Power Class 3 (<= 24W)
Power Class 4 (<= 32W) (default)
CFP2
Power Class 1 (<= 3W)
Power Class 2 (<= 6W)
Power Class 3 (<= 9W)
Power Class 4 (<= 12W) (default)