INPut:ATTenuation?
Description This query returns a value indicating the current attenuation
setting OR the minimum/maximum attenuation setting.
Syntax
INP:ATT? [<wsp><value>]
Parameters The <value> parameter is optional and can be
“MIN” to obtain the minimum setting for the current wavelength
“MAX” to obtain the maximum setting for the current
wavelength
Response
The attenuation value in the format “999.99”. The units are dB.
Note that, depending on the current measurement mode, the
response will include different parameters:
In Absolute mode:
In Reference mode:
In Offset mode:
Example
INP:ATT? MIN or
INP:ATT?
response
actual attenuation
=
response
actual attenuation reference value(INP:OFFS?)
–
=
response
actual attenuation wavelength-specific offset
+
=