Instructions for use 1 general – Glow-worm Chatsworth 4 User Manual

Page 8

Advertising
background image

8

221907C

6225

590 WIDE FRAME
547 STANDARD FRAME

21

62 DOVEDALE
76 CHATSWORTH

652 WIDE FRAME

630 STANDARD FRAME

Dimensions are
the same for the
Dovedale except
where shown

GENERAL OVERALL
DIMENSIONS
Chatsworth illustrated

Diagram 7

BATTERY

9461

DATA LABEL

Instructions for Use

1 General

STEP 7. Place six small fuel effect pieces on the six flat areas
of the rear support starting from the outside, leaving gaps
around the pieces. The two outside pieces touch the sides of
the fire.

STEP 8. Place five small fuel effect pieces on the top of the rear
support starting from the outside overlapping slightly the
previously fitted pieces and touching the rear of the fire. Leave
gaps around the front and side of the pieces. The two outside
pieces do not touch the sides of the fire.

When you have fitted all the small pieces you may have to adjust
some slightly to maintain constant gaps.

To Replace the Battery - this can be done by

the user

The battery, supplied, should, under normal usage last for
about 18 months.

The replacement is 9V and we recommend that it be of the
alkaline type which can be bought locally.

Remove the fret and ash pit cover, see diagram 5.

Replace the battery as shown in diagram 7.

Replacement Parts

If replacement parts are required apply to your local supplier.

Remove the ashpit cover, see diagram 5.

Quote the name of the appliance indicated on the rear of the
ashpit cover.

Quote the serial number of the fire front found on the label
attached to the chassis to the left of the electrical control box,
see diagram 7.

Quote the back boiler units name and serial number on the data
label which can be found on the base of the boiler, see
diagram 7.

References in these instructions to British Standards and
Statutory Regulations and Requirements apply only to the
United Kingdom.

For Ireland the rules in force must be used.

1 General Notes and Information

There is one cardboard carton, which contains all the parts
necessary for the fitting of the fire front, see diagram 1.4.

Wherever possible, all materials, appliances and components
to be used should comply with the requirements of applicable
British Standards.

Where no British Standard exists, materials and equipment
should be fit for their purpose and of suitable quality and
workmanship.

1.1 Important Notice

This fire front is for use only on G20 gas.

The back boiler is supplied pre-set to a maximum heat output
setting, for the 45/4 BBU: 11.72 kW (40000 Btu/h), for the 54/4
BBU: 14.21 kW (48500 Btu/h).

These values are permitted and must not be increased when
using the boiler in combination with a Chatsworth 4 or a
Dovedale 4 firefront.

Advertising