1 General

SEALING
PLATE

A new data label, supplied with fire front loose items pack, must
be stuck over the top of the BBU data label, see diagram 1.1.
Care must be taken when oversticking the label on top of the
original as not to obscure the boiler serial number.

The fire front is fitted with a flue blockage safety device which
will shut it down if there is a lack of oxygen. The principle by
which this operates is that when there is a depletion of oxygen
resulting from a build up of combustion products. The flame on
the pilot light will become unstable and lift up off the thermocouple.
This will deactivate the mag unit in the gas control valve, cutting
off the gas supply.

If the fire shuts down frequently for no apparent reason the first
things to check are the chimney and air inlets into the room. Any
problems found must be put right, by a competent person, and
a full operational test carried out before the fire is used again.

IN ALL cases the room must be ventilated before attempting to
relight the fire.

The flue blockage safety device incorporates the electrode,
thermocouple and pilot assemblies.

The flue blockage safety device MUST NOT be adjusted or
disconnected. It must be serviced strictly in accordance
with the instructions in this book. Any unauthorised
interference could result in the device failing to operate,
creating a potentially dangerous situation. If replacing, use
only the correct and approved parts.

Sealed components must not be interfered with.

Servicing instructions and identification of parts is given in
Sections 6, 7, 8 and 9.

It is essential that only genuine Glow-worm parts are used.

All WARNINGS and cautions in these instructions must be
observed.

Sheet Metal Parts

WARNING. When fitting or servicing this fire front, care should
be taken when handling sheet metal parts, to avoid any possibility
of personal injury.

1.2 Statutory Requirements

The fitting of this fire front must be done by a competent person,
in accordance with the current issue and relevant requirements
of:-

Manufacturer’s instructions, supplied.

The Gas Safety (Installation and Use) Regulations, The Building
Regulations, The Building Standards (Scotland) Regulations,
(applicable in Scotland), The Health and Safety at Work Act,
The Control of Substances Hazardous to Health, The Electricity
at Work Regulations and any applicable local regulations.

Detailed recommendations are contained in the current issue of
the following British Standards and Codes of Practice:-

BS1251, BS5440 Part 1 and 2, BS5871, BS6891.

Manufacturer’s instructions must not be taken as overriding
statutory requirements.

1.3 Certification

This fire front is certificated for performance and safety. It is,
therefore, important that no alteration is made to the fire front
without permission, in writing, from Hepworth Heating Ltd.

Any alteration that is not approved by Hepworth Heating Ltd.,
could invalidate the certification, the warranty and could also
infringe the statutory requirements.

DATA LABEL (FIRE)

1.4 Data

Injector

Part No. 205739

Pressure setting

Hot 17.6mbar (7.1 in wg)

Nett Heat input nominal

6.07kw (20725 Btu/h)

Total appliance

Unpacked weight

(Approx. 20kg)

Data label is positioned, see diagram 1.1.

1.5 Fire Location

This fire front can only be fitted to Glow-worm 45/4 and 54/4
back boiler units which itself has been installed in accordance