9 Cylinder installation

9.1

Cylinder device description

15

14

22

20

21

1

13

11

12

16

17

3

19

23

24

25

26

18

2

3

4

5

6

7

9

8

10

Key

1 Hot water connection

2 expansion relief valve (one-way valve, 6.0 bar)

3 Pressure limiting valve (3.5 bar) with line strainer

4 Cold water connection

5 Pressure-controlled cold water connection

6 Connection for hot water expansion vessel

7 Cylinder connection

8 Hot water expansion vessel

9 Tundish

10 Cylinder drain valve (not supplied)

11 Return line (solar circuit)

12 solar collector temperature sensor

13 Cold water pipe

14 solar circuit safety thermostat (TCO), set to 80 °C, to be connected

with the solar pump in order to isolate this heat source

if there is a malfunction in the solar control.

15 solar circuit immersion sleeve (length 70mm dia. 8mm) (TaC 2)

16 supply line (solar circuit)

17 2- pole circuit breaker for electric immersion heater

18 electric immersion heater with thermostat and safety thermostat

(20°C to 65 °C) (length 70mm dia. 8mm)

19 Return line (gas-fired boiler)

20 Reheating circuit immersion sleeve (TaC 1)

21 Reheating circuit safety thermostat, set to 80 °C, to be connected

to the 2-way motorised valve in order to isolate the primary

heat source if a malfunction occurs.

22 Cylinder thermostat (25 °C to 65 °C)

23 2 -way motorised valve

24 Supply line (gas-fired boiler)

25 Circulation line connection

26 Temperature and pressure relief valve (90 °C, 7 bar)