0020115479_03 - 10/12 - Glow-worm

- 20 -

INSTALLATION

9.7

electrical installation

a

Improperly executed electrical connections can impair

the operational safety of the unit.

- Only a competent person approved at the time by

the Health and Safety Executive may carry out the

electrical installation.

e

Without earthing, life-threatening voltage can reach

the piping and water draw-off points.

- Earth the cylinder.

Wiring should be installed by a qualified heating engineer in

accordance with the building regulations, Part P of the current IEE

regulations, and all other applicable regulations and directives.

You can use standard commercial cables (H05RR-F 3G1.5 or

H05VV-F 3G1.5) for the wiring:

- Cross-section of conductors: 1.5 mm

2

- Torque for strain relief: 1,5 Nm.

- Maximum length of bus cables: 300m.

230 V supply lines and bus cables must be laid separately above

lengths of 10 m.

The discharge pipes of the tundish, drain valves, and motorised

valves etc. must be laid at a distance from electrical components.

9.7.1

Wiring

Wiring can be accommodated via the Glow-worm Smart Wiring

Centre or Systempro as a system solution. This enables Glow-

worm dual-channel eBUS controllers (low-voltage) to be used

along with 230 V valves to give control of Hot Water and Heating

systems. Alternatively, using a standard 230 V cabling box and

controls.

All wiring must be carried out in accordance with BS

7671: "Requirements for electrical installations" (IEE

wiring regulations, current edition).

Smart Wiring Centre will accomodate 1 CH plus 1 DHW

zone. Systempro will accomodate up to 3 CH zones

plus 1 DHW zone.

9.7.3

Mounting the drain valve

- Mount a drain valve in the cold water pipe at the lowest point

between the cylinder and the safety assembly.

The drain valve must be provided by the customer. We

recommend applying a hose which reaches about 1 m under the

base of the cylinder to the outlet of the drain valve.

9.7.4

electrical connection of control components

6

1

2

7

5

10

9

3

4

5

8

Key

1 Cover cap for reset button for reheating circuit TCO

2 Reheating circuit temperature controller

3 Reheating circuit immersion sleeve (TaC 1)

4 electric immersion heater cover

5 solar circuit immersion sleeve (TaC 2)

6 Cover cap for reset button for solar circuit TCO

7 solar circuit safety thermostat (TCO)

8 electric immersion heater

9 Reheating circuit safety thermostat

10 Cylinder thermostat