Installation – Glow-worm Clearly Solar Cylinders User Manual

Page 23

Advertising
background image

0020115479_03 - 10/12 - Glow-worm

- 21 -

INSTALLATION

9.7.5

Cylinder thermostat and thermal cut out (TCO)

for the reheating circuit

1

2

3

4

5

6

14

13

12

11

10

7
8

9

Key:

1 Cylinder thermostat

2 Cylinder thermostat temperature sensor

3 lower immersion sleeve

4 Terminal for cylinder thermostat protective earth

5 Cylinder thermostat terminal 1

6 Cylinder thermostat terminal 2

7 Cylinder thermostat terminal C

8 bridge

9 Reheating circuit TCO terminal 2

10 Reheating circuit TCO protective earth terminal

11 Reheating circuit TCO C terminal

12 Reheating circuit TCO reset button

13 Reheating circuit TCO temperature sensor

14 Reheating circuit safety thermostat (TCO)

Disconnect from the mains supply before you remove any of the

underlying component covers.

9.7.6

solar circuit thermal cut out (TCO)

1

2

3

4

5

Key:

1 solar circuit thermal cut-out (TCO)

2 solar circuit TCO reset button

3 solar circuit TCO terminal C

4 solar circuit TCO protective earth terminal

5 solar circuit TCO terminal 2

The live supply to the solar pump MUST be run in series through

terminals 3 and 5 from the solar control to the pump for this to be

operative as the solar TCO.

9.7.7

Connecting up the electric immersion heater

The Glow-worm Flurocyl

2

solar cylinders are fitted with an electric

immersion at the factory.

9.7.8

electrical connection of electric immersion

heater

1

2

3

4

5

4

2

3

1

5

Key

1 Protective earth terminal (Pe)

2 Cable grip

3 Neutral conductor terminal (N)

4 Outer conductor terminal (l)

5 electric immersion heater

e

Without earthing, life-threatening voltage can reach

the piping and water draw-off points.

- Earth the cylinder.

• The electric immersion heater must be earthed.

• Dismantle the electric immersion heater cover.

• Install a separate electrical power supply for the electric

immersion heater in accordance with current IEE regulations

(BS 7671).

- Use heat-resistant cables (H05BN4-F 1.5 mm² 3 core HOFR

sheathed flexible cable) for the cabling of the electric

immersion heater.

- Use the cable grip (2) to firmly secure the supply cable of the

immersion heater.

- Connect the electric immersion heater to the power mains via

double pole isolating switch with a contact separation of at

least 3 mm in both poles.

- Protect the circuit using a 13 A fuse. Mount the cover for the

electric immersion heater.

Only switch the immersion heater on once the cylinder

is completely full.

With the circuit breaker, the electric immersion heater can be

switched on if the reheating device has malfunctioned.