Installation – Glow-worm Clearly Solar Cylinders User Manual

Page 16

Advertising
background image

0020115479_03 - 10/12 - Glow-worm

- 14 -

INSTALLATION

The Flurocyl

2

solar cylinder is available in three sizes: 200, 250,

and 300 litres. The containers are made from stainless steel with

EPS insulation. The cylinder is supplied along with all required

cold and hot water control devices and a 2-way motorised valve.

The cylinder works with the pressure of the water supply line

and does not need a cold water tank for its supply. The cylinder

has hot and cold water connections with a diameter of 22 mm.

To enable the cylinder to work as well as possible, a cold water

supply with an appropriate pressure and flow rate is required.

9.1.1

Cylinder operating elements

5

4

1

2

7

8

3

6

Key

1 Cover cap for reset button for reheating circuit TCO

2 Reheating circuit temperature controller

3 electric immersion heater cover

4 Cover cap for reset button for solar circuit TCO

5 solar circuit safety thermostat (TCO)

6 electric immersion heater

7 Cylinder thermostat

8 Reheating circuit safety thermostat

The following are pre-mounted at the factory for the Flurocyl

2

solar cylinder:

Cylinder thermostat (7) and reheating circuit safety thermostat (8)

Electric immersion heater (6) with safety thermostat and cylinder

thermostat

Solar circuit safety thermostat (5)

The cylinder must be properly wired in order to comply with G3

building regulations.

You must connect the solar pump to the solar

controller via the solar circuit safety thermostat.

The thermostat switches the solar pump off if the

temperature of the hot water in the cylinder exceeds

80 °C.

9.1.2

electric immersion heater operating elements

1

2

3

4

5

1

2

3

Key

1 electric immersion heater temperature controller

2 electric immersion heater TCO reset button

3 electric immersion heater

The cylinder is equipped with an additional electric immersion

heater (3) with a heating output of 3 kW. The electric immersion

heater is located behind the top front cladding. The electric

immersion heater is designed for use in unvented cylinders and

has a thermostat with a temperature controller (2) and a safety

thermostat (TCO) with a reset button (1).

If you need to make a replacement, you must use

the correct electric immersion heater with a safety

thermostat for overheating protection. Only use

original replacement parts from Glow-worm. Always

replace the immersion heater gasket when parts are

replaced.