INSTALLATION
- 12 -
4.2 Flue confi guration description
4.2.1 Horizontal concentric fl ue Ø 60/100 mm
or Ø 80/125 mm (C13 type installation)
a
If the terminal is at less than 1.80 m from the
ground, you must install a terminal protection kit.
Ø 60/100 mm
L
63
1
Key
1 Gasket (fi tted)
Ø 80/125 mm
L
1
Key
1 Gasket (fi tted)
Type
Max length
Ø 60/100
8 m
Ø 80/125
20 m
Type
Max length
Ø 60/100
512 mm
4.2.3 Vertical concentric fl ue Ø 60/100 mm
or Ø 80/125 mm (C33 type installation)
a
If the terminal is at less than 1.80 m from the
ground, you must install a terminal protection kit.
L
Type
Max length (L)
Ø 60/100
8 m
Ø 80/125
20 m
Each time an additional 90° bend is necessary (or 2 at 45°), the
length (L) must be reduced by 1 m.
L
Each time an additional 90° bend is necessary (or 2 at 45°), the
length (L) must be reduced by 1 m.