Maintenance – Glow-worm Flexicom hx User Manual

Page 43

Advertising
background image

0020107230_04 - 12/14 - Glow-worm

MAINTENANCE

- 43 -

Diagram 14.8

13003

Diagram 14.9

13003

Diagram 14.10

13004

14.15 Casing Seal

Refer to Section 12.8.

14.16 Access to User interface and Main
PCB

For access, refer to section 14.1.
Hinge down the control box and unclip the rear cover to gain
access.
Remove electrical connections from main PCB noting their
positions for replacement.
Unclip main PCB and remove, see diagram 14.8.
Unclip user interface and remove.
For replacement, see diagram 14.9 and ensure that the user
interface connection cable is refi tted.
NOTE: When re-fi tting any of the control boards make sure you
support the control box to avoid straining hinges as you push
down and clip back into place.

14.17 Control Box

For access, refer to section 14.1.
Hinge down the control box and unclip the rear cover to gain
access.
Remove relevant electrical connections from main PCB and
grommets from the control box.
MPORTANT: Support the control box whilst undoing the hinges.
Remove the hinge securing screws accessed from beneath the
boiler and remove the control box, see diagram 14.10.

14.18 Fuse - Main PCB - Control Box

For access, refer to section 14.16.
The fuse is located at the top left hand corner of the main PCB,
see diagram 14.8.

14.19 Installer Interface Electrical Cartridge

Remove the Installer Interface securing screw accessed from
beneath the boiler.
Carefully pull down the electrical cartridge, disconnect the
cables.

Advertising