Installation – Glow-worm Flue User Manual

Page 15

Advertising
background image

0020095198_02 - 06/11 - Glow-worm

INSTALLATION

- 15 -

FLAT ROOF

1.

TERMINAL

2.

3.

5.

100-110

5

SECURING

COLLAR

SECURING

SCREW

SECURING

SCREW

6.

DO NOT

SECURE

4.

TERMINAL

PITCHED ROOF

100-110

5

SECURING

COLLAR

1.

2.

3.

4.

5.

SECURING

SCREW

SECURING

SCREW

6.

DO NOT

SECURE

5.5

flue Terminal cutting

Should the clearances above the appliance to the flue terminal

not allow for extensions, it is permitted to cut the flue terminal

ensuring the relationship of flue and air duct lengths are

retained.

5.6

flue extension completion

With the flue terminal positioned in the roof, measure the

length of the pipe required to complete the connection between

terminal and extension. If a telescopic length cannot be used,

then an extension pipe can be cut to the correct length. Cut the

flue to the desired length measuring from the ‘O’ ring end and

discard the plain end of the tube. The cuts must be square and

made free of burrs to allow correct assembly.

noTe: The flue pipe is 10mm longer than the air pipe.

Carefully push the terminal assembly upwards to allow room

for fitting the final flue piece. Fit a fixing bracket to the terminal

assembly. Pull the terminal assembly down and join to the flue

system. Ensure that the terminal is making a weather tight seal

on the weather collar. Secure the fixing bracket fitted to the

terminal to the roofing struts or a purpose made batton.