Installation, Rear flue, Side flue – Glow-worm Flue User Manual
Page 9

0020095198_02 - 06/11 - Glow-worm
INSTALLATION
- 9 -
3 Top Horizontal Telescopic flue Kit
Ø60/100 - Pt. no. a2043600
Check the contents of your kit.
3.1
flue length and Terminal position
Refer to your Installation instructions supplied with the
appliance to confirm the flue length available and location of the
flue terminal, then proceed as follows:
• With the flue elbow temporarily fitted, measure the distance
from the external wall to the elbow.
noTe: * If fitting the sealing collar, add a further 12mm to the
overall length ‘Y’, see diagrams below.
• Set the flue ducts to the required length ‘Y’. If the
measurement ‘Y’ exceeds the telescopic flue length, then the
appropriate length of extension pipe will be required.
15610
ReaR flUe
*
‘Y’
1561
1
sIDe flUe
*
‘Y’
DO NOT cut the telescopic flue, if the flue length
cannot be achieved, the standard flue or extensions
should be used.
If desirable the flue can project to a maximum of 600mm
beyond the outside wall face.