2 Telescopic Direct Rear flue Kit Ø60/100

- Pt. no. a2043500

Direct rear flues are only possible with certain

boilers, check the instructions provided with your

boiler.

Check the contents of your kit.

SEALING

TAPE

SEALING

COLLAR

FLUE SECURING

SCREWS (3 OFF)

CLAMPING BAND

2.1

flue length and Terminal position

Refer to your Installation instructions supplied with the

appliance to confirm the flue length available and location of the

flue terminal, then proceed as follows:

• Measure the distance from the external wall to the appliance

mounting face ”Y”, see diagram below.

• Set the flue to the required length ‘Y’ plus 24mm min to

28mm max.

*

Y + 24 to 28

INSIDE

WALL

FACE

OUTSIDE

WALL

FACE

*

noTe:

If fitting sealing

collar an

additional 12mm

is required

noTe: If fitting the sealing collar, add a further 12mm to the

overall length.

noTe: DO NOT cut the telescopic flue, if the flue length cannot

be achieved, the standard flue or extensions should be used.

However if necessary the flue can project to a maximum of

600mm. beyond the outside wall face.

• Align the air duct seams.

• Mark and drill a 3mm hole in the air duct, taking care not to

pierce the inner flue duct.

• Secure the joint with the screws and tape provided.