1 General

The instructions consist of three parts, Installation and Servicing
Instructions for the Back Boiler Unit, Installation and Servicing
Instructions for the Fire Front and Instructions for Use, which
includes the Guarantee Registration Card. The instructions are
an integral part of the appliance and must, to comply with the
current issue of the Gas Safety (Installation and Use)
Regulations, be handed to the user on completion of the
installation.

This boiler is for use only with a specially designed Glow-worm
Gas Fire Front, see Table 1.

This boiler is NOT suitable for fitting to a precast flues.

The boiler is delivered in one pack which contains all the parts
necessary for the installation.

If installing the back boiler unit and fire front at the same time
please read both sets of instructions before starting.

1 General Notes and Information

IMPORTANT NOTICE

The back boiler is fitted with a safety device which will shut it
down if there is a lack of oxygen. If the back boiler shuts down
frequently for no apparent reason. The first things to be
checked are the chimney and air inlets into the room. Any
problems found must be put right, by a competent person,
before the back boiler is used again.

This back boiler is for use only on G20 gas.

Wherever possible, all materials, appliances and components
to be used shall comply with the requirements of applicable
British Standards.

Where no British Standard exists, materials and equipment
should be fit for their purpose and of suitable quality and
workmanship.

Sheet Metal Parts

WARNING. When installing or servicing this back boiler care
should be taken when handling the edges of sheet metal parts
to avoid any possibility of

personal injury.

1.1 Statutory Requirements

The installation of this back boiler unit must be carried out by a
competent person in accordance with the current issue and
relevant requirements of:

Manufacturer’s instructions, supplied.

The Gas Safety (Installation and Use) Regulations,

The

Building Regulations, The Building Standards (Scotland)
Regulations (applicable in Scotland), Local Gas Undertaking,
Bye-laws of the Local Water Company, The Health and Safety
at Work Act, Control of Substances Hazardous to Health, The
Electricity at Work Regulations and any applicable local
regulations.

Detailed recommendations are contained in the current issue of
the following British Standards and Codes of Practice,

BS6891, BS5449, BS5546, BS6700, BS5871, BS5440 Part 1
and 2, BS6798, BS1251, BS7478, BS7593, BS7671.

Manufacturer’s notes must not be taken as overriding statutory
requirements.

1 General

1.2 Data

Gas connection

Rc

1

/

2

(

1

/

2

inBSPT)

Water connection

Supplied in fittings pack

Electrical supply

230V~50Hz fused 3A

Weight, about

35kg

Water content

3.11Litres

Injector

3.6mm

Dimensions are given in millimetres (except as noted).

Data Label: Front, centre on base.

The Seasonal Efficiency Domestic Boilers UK (SEDBUK)
is 78.6%.

The value is used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.

1.3 Gas Supply

The gas installation shall be in accordance with the current
issue of BS6891.

The supply from the governed meter must be of adequate size
to provide a steady inlet working pressure of 20mbar (8in wg)
at the back boiler.

On completion test the gas installation using the pressure drop
method and suitable leak detection fluid, purge in accordance
with the current issue of BS6891.

1.4 Electrical Supply

WARNING. This back boiler must be earthed.

All system components shall be of an approved type and shall
be connected in accordance with the current issue of BS7671
and any applicable local regulations.

Connection of the back boiler and system controls to the mains
supply should be through a double pole isolating switch, fused
3A having a minimum contact separation of 3mm in both poles.

Alternatively, a fused 3A 3 pin plug and unswitched socket
outlet to the current issue of BS1363 may

be used.

Wiring to the back boiler must be PVC (85

o

C) insulated type to

the current issue of BS6500 Table 16, not less than 0.75mm

2

(24/0.20mm).

1.5 Site Requirements

Refer to diagram 1.1 for dimensions appropriate to the back
boiler.

For all types of installation a standard sized builder’s opening
is required, see diagram 1.2.

It is important that the opening is cleared of debris

and

mortar.

It is recommended that the access hole for pipework into the
fireplace or builder’s opening is either at the left hand or right
hand side of the chimney breast. If access is required at both
sides then it may be necessary to prepare some of the
connections before fitting the back boiler into the builder’s
opening.

The prepared base for the back boiler must be level.

NOTE: For wider openings corner infills may be required when
fitting some fire fronts. The infills are for cosmetic reasons only,
see diagram 1.3.

Refer to Table 2 for dimensions of fire front fixing wall face
which must be true.