8 servicing – Glow-worm 56/3e Back Boiler User Manual

Page 23

Advertising
background image

23

221725B

8 Servicing

Diagram 8.8

6301

EARTH
POST

FRONT
VIEW

EARTH
POST

ELECTRODE

TOP VIEW

SPARK GAP
3 +1 or -0.5

THERMOCOUPLE

Diagram 8.7

6834

COPPER
WASHER

MAIN BURNER
INJECTOR

8.8 Ignition Lead

Inspect the ignition lead for wear or damage, clean or replace as
necessary.

8.9 Back Boiler Flueways

Remove the spigot duct, see diagram 8.10.

Remove the draught diverter plate by slackening the two side
securing screws and removing the rear securing screw, see
diagram 8.10.

Lift out the flueway baffles, see diagram 8.11.

Place a sheet of paper in the base of the combustion chamber.

Clean the boiler flueways with a suitable stiff brush.

To make sure that the flueways are clean, view with the aid of
a mirror or reflector.

Remove the paper and debris.

When refitting make sure that the baffles are correctly seated in
the back and middle flueways, see diagram 8.11.

NOTE: If the heat exchanger has been turned the baffles must
still be fitted into the back and middle flueways.

Refit the draught diverter plate.

Refit the control/burner assembly.

Diagram 8.9

6207

FLUE
BLOCKAGE
SAFETY
DEVICE

SECURING
SCREW (2)

PILOT TUBE
NUT

Diagram 8.11

7195

FLUEWAY
BAFFLES

HEAT
EXCHANGER

BACK
FLUEWAY

Diagram 8.10

6835

SECURING
SCREW (3)

DRAUGHT
DIVERTER
ASSEMBLY

DRAUGHT
DIVERTER
PLATE

SECURING
SCREW (2)

SPIGOT DUCT

MIDDLE
FLUEWAY

Advertising